Lyell Collection

Geological Society, London, Engineering Geology Special Publications

Lyell Centre  |   Lyell Collection  |   Subscriptions   |   Geological Society  |   Email alerts  |   Online bookshop  |   Help


Keywords:
Author:
Advanced search>>
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maharaj, R. J.
Right arrow Search for Related Content
Geological Society, London, Engineering Geology Special Publications; 1998; v. 15; p. 61-69;
DOI: 10.1144/GSL.ENG.1998.015.01.07
© 1998 Geological Society of London

Section 1: Coastal and fluvial geohazards

The performance of some coastal engineering structures for shoreline stabilization and coastal defence in Trinidad, West Indies

Russell J. Maharaj

Landslide Section, Disaster Prevention Research Institute, Kyoto University, Uji, Gokasho, Kyoto 611, Japan and Institute of Marine Affairs, Hilltop Lanes, Chaguaramas, Trinidad and Tobago, West Indies

Coastal erosion in Trinidad has caused a loss of land and subsequent damage to many coastal engineering structures. Damage includes roadway failures, loss of agricultural land, coastal flooding and damage to property. In many areas, structural engineering measures have been implemented to prevent these from recurring. An example of erosion and structural measures used in a segment of rapidly eroding coastline along the east coast of the island is presented. The site is part of a coastal section of the largest wetland on the island, the Nariva Swamp, through which drains the largest river system, the Nariva River. Structural measures used include steel sheet piled revetment, steel-reinforced concrete retaining walls, gabion basket retaining structures, boulder splash aprons, a steel-reinforced concrete pile cluster, concrete columns and blocks and boulder riprap. All these an show signs of structural failure, and some have already collapsed. Failures include spelling and cracking of concrete; rebar corrosion; steel pile corrosion; foundation settlement under retaining walls and structures, with subsequent surfical cracking; basal foundation sediment scour and undermining; wave and fluvial induced removal of rip-rap and splash apron boulders, and seasonal burial and sedimentation of the splash apron and concrete pile cluster. Based on this study, it appears that construction-induced high energy conditions and oversight in design and construction were partly responsible for failures.